|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
File name: TFS133.doc version 1.4 10.10.2001 VI TELEFILTER 1. Measurement condition : Filter Specification TFS 133 1/5 Ambient temperature TA: Input power level: Terminating impedances in fc *) : 23 C 0 dBm for input: for output: 1656 /e - 7,292 pF. 2084 /e - 6,964 pF. 2. Characteristics : Remark: Reference level for the relative attenuation arel of the TFS 133 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed to 133.0 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. All specified parameters have to be reached in the operating temperature range ( OTR ) . Data Insertion loss (Reference level) Nominal frequency Centre frequency Centre frequency Amplitude ripple in Amplitude ripple in Bandwidth in OTR : 0,2 dB - band width 0,4 dB - band width 20 dB - band width arel 80 200 kHz kHz MHz MHz MHz MHz fN 50 kHz fN 50 kHz (p-p) fN 100 kHz: ae typ. value 7,2...8,2 * ) 133,007 350...400 500...580 2720 0,1 0,2 35 45 70 70...50 0,78 60 15 kHz kHz kHz dB dB dB dB dB dB s ns dB dB tolerance / limit max. 9 dB fN fc in OTR fc at ambient temperature TA = 23 C fN 80 kHz (p-p): fN 200 kHz (p-p): MHz 133 MHz 133 0,025 MHz 133,007 0,018 MHz max. 0,2 max. 0,4 min. 0,16 min. 0,40 max. 3,6 max. 0,2 max. 0,4 min. min. min. min. max. max. min. max. 20 35 20 20 1 1 10 10 dB dB MHz MHz MHz dB dB dB dB dB dB s s dB dBm Relative attenuation fN ..... fN kHz .... fN fN 80 fN 1,8 fN 6 fN - 132 fN + 39 MHz .... fN 6 MHz .... fN 39 MHz .... fN 39 MHz .... fN + 887 Group delay ( mean value) Group delay ripple Return loss with matching network (S11 / S22 ) in Input power level Frequency inversion temperature ( To ) : Temperature coefficient of frequency ( Tcf ) : Frequency deviation of fc over temperature: ** ) Operating temperature range ( OTR ) : Storage temperature range : 37 C - 0,036 ppm/K fc(Hz) = Tcf(ppm/K) x (T - To) x fO (MHz) - 5 C ... + 80 C - 40 C ... + 85 C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fO = fTo is reference frequency fc at frequency inversion temperature (To ) Generated: Wadim Dunzow Checked/Approved: VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS133.doc version 1.4 10.10.2001 VI TELEFILTER Filter Specification TFS 133 2/5 3. Construction and Pin Connection (All dimensions in mm) TFS 133 N40 Datecode: L M N Year+week 1999 2000 2001 ... ... Pin 9 Input. Pin 10 Input RF Return. Pin 4 Output. Pin 5 Output RF Return. Pin 1-3, 6-8 - PackageGround. 4. 50 matching network ( about matching element values see Application Note.) : Scheme 1 1 10 9 L1 8 7 6 2 3 4 L4 5 L2 50 L3 50 Scheme 2 1 10 9 L1 8 7 6 2 3 4 C2 5 L2 50 C1 50 For final test we use scheme 1. VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS133.doc version 1.4 10.10.2001 VI TELEFILTER 5. Stability characteristics : Filter Specification TFS 133 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 2. Vibration: 3. Change of temperature -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N 4. Resistance to solder heat (reflow):max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing : Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer EMBOSSED CARRIER TAPE 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) Do Po P 2 W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 11,5 0,1 0,6 2 0,1 8 0,1 1,5 5,6 0,1 11,8 0,1 21,5 0,1 E A o F D CT B o 1 W G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 W2(max) N(min) C : : : : : 330 24,4 +2,0 30,4 60 13 +0,5/-0,2 C A N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS133.doc version 1.4 10.10.2001 VI TELEFILTER 7. Air reflow temperature conditions : Filter Specification TFS 133 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFS133.doc version 1.4 10.10.2001 VI TELEFILTER 8. History : Version 1.0 1.1 Reason of Changes Filter Specification TFS 133 5/5 Name M. Senior Dr. Wall Date 18.05.2001 01.06.2001 Generation of specification according to customer requirements. Add maximum value for insertion loss of 9 dB. Correct tape and reel information. Change package. Add possible configuration of matching networks. Change definition of centre frequency : from 3 dB to 20 dB ( see : 2. "Characteristics - Remark " ) Add requirement for ILo in OTR. Correct OTR according to customer requirements. Correct frequency range for return loss . 1.2 Dunzow W. 21.06.2001 1.3 Dunzow W. 09.07.2001 1.4 - add typical values of filter and termination impedances; Dunzow W. - change name of specification : from "Preliminary specification" to "Filter specification". 10.10.2001 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS133.doc Directory: R:\info\global\spezifikationen Template: C:\Program Files\Microsoft Office\Templates\Normal.dot Title: Measurement condition Subject: Author: Dr. Wall Keywords: Comments: Creation Date: 10/08/01 6:47 PM Change Number: 17 Last Saved On: 09/26/02 3:09 PM Last Saved By: Authorized User Total Editing Time: 1 Minute Last Printed On: 10/01/02 8:59 AM As of Last Complete Printing Number of Pages: 5 Number of Words: 800 (approx.) Number of Characters: 4,560 (approx.) |
Price & Availability of TFS133 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |